Our Products

Rotary Evaporator

Laboratory equipment

Jacketed Reactor

Contact Us

General Purpose Water Baths General Purpose Water Baths

2019-9-4 · bath. Not on your work surface. PolyScience Water Baths, available in a range of capacities from 2 liters to 28 liters in both economy and digital models, provide the perfect blend of scientific accuracy and utility for day-to-day laboratory tasks. 86-87 Digital 88-89 Economy 90-91 General Purpose Water Bath Accessories General Purpose Water Baths

How to Clean a Waterbath (When You Can't Avoid it Any .

2012-4-20 · There's something disconcerting about going to incubate a sensitive and irreplaceable sample in a water bath, only to be confronted by the Creature from the Black Lagoon. Unfortunately, water baths are an inviting habitat for all kinds of life, are often shared by many users, and are a perennially unpopular item to clean. To help you overcome your fears of the monsters lurking in the water .

Lab SOP for Whole Genome Sequencing on Miseq

2019-5-3 · This SOP describes the standardized laboratory protocol for whole genome sequencing . Water, molecular-grade (Fisher Scientific, # BP24701 or equivalent) 6.6. . Immediately cool in an ice-water bath (made by combining approximately 3 parts ice and

Operator's Manual General Purpose Water Baths

110-031 VWR/EN 2 Introduction Thank you for choosing this Water Bath. It is designed to handle a wide range of laboratory procedures including: incubation, inactivation and agglutination as well as most pharmaceutical, serological, biomedical and industrial

Water Baths: Heated, Digital & Shaker Baths - Cole-Parmer

Water baths are ideal for maintaining temperature set points over a long period of time. Different sizes and depths of the bath chamber are available to meet your application.

ESC, Ft. Meade, MD Standard Operating Procedure

2017-7-24 · de-ionized water or ethanol. Once the de-ionized water or ethanol has reached the temperature of interest, conduct the accuracy check. The NIST thermometer must be suspended in the liquid in the flask, not resting on the bottom of the flask. 10.4 A water bath is used, where applicable, to check the temperature of the

STANDARD OPERATING PROCEDURE FOR VARIOUS .

2015-6-3 · to standard operating procedure (SOP) and using personal protective equipment (PPE) where applicable. The use of UV in the laboratory is governed by „The control of Artificial Optical Radiation at Work Regulations 2010‟ UV light emitted from a transilluminator .

Standard Operating Procedure: Glassware Cleaning

2016-12-15 · careful not to spill base everywhere!!!), rinse with DI water 3 times (make sure you rinse both the inside and the outside surface). After this, transfer the glassware to the acid bath and let it soak (3 h – overnight; take care to avoid air bubbles). Once this is done, rinse with DI water 3 times, and finally leave soaking in DI water.

T10-001A Care and maintenance of water baths

2013-5-15 · Bath water For the Stuart baths we recommend water, preferably distilled or deionised, with neutral pH. Ultra pure deionised or RO water with a resistivity >1Mohm should not be used, as this can leach the iron from the stainless steel and lead to corrosion. If necessary, add a little tap water to the pure water in the bath.

SOP On Safety In Quality Control Laboratory .

This SOP on Safety in Quality Control Laboratory is applicable for guidelines regarding safety hazards occurring during laboratory working and to guide on safe handling of various reactions during analysis, and handling some of corrosive and poisons like Potassium Bromide in Quality Control Department at manufacturing site. . Use a water-bath .

SOP On Safety In Quality Control Laboratory .

This SOP on Safety in Quality Control Laboratory is applicable for guidelines regarding safety hazards occurring during laboratory working and to guide on safe handling of various reactions during analysis, and handling some of corrosive and poisons like Potassium Bromide in Quality Control Department at manufacturing site. . Use a water-bath .

Standard Operating Procedure for Base Bath Cleaning .

2014-4-10 · To make a new base bath, potassium hydroxide (500g) should be first dissolved in 1L water in a beaker. Beware that the solution will become very hot upon dissolution. This solution should be added to 12L of isopropanol in a large Nalgene container. 4. Base Bath Waste Disposal Base bath should be disposed of like any other caustic solution.

Operator's Manual General Purpose Water Baths

110-031 VWR/EN 2 Introduction Thank you for choosing this Water Bath. It is designed to handle a wide range of laboratory procedures including: incubation, inactivation and agglutination as well as most pharmaceutical, serological, biomedical and industrial

T10-001A Care and maintenance of water baths

2013-5-15 · Bath water For the Stuart baths we recommend water, preferably distilled or deionised, with neutral pH. Ultra pure deionised or RO water with a resistivity >1Mohm should not be used, as this can leach the iron from the stainless steel and lead to corrosion. If necessary, add a little tap water to the pure water in the bath.

SOP for Operating Procedure of Water Bath : Pharmaceutical .

2 days ago · To lay down the procedure for operation of the water bath. 2.0 SCOPE This procedure is applicable to the water bath, installed at Microbiology laboratory in QC. 3.0 RESPONSIBILITY 3.1 Doing: Technical Assistant 3.2 Checking: Executive/ Manager 4.0 ACCOUNTABILITY Head of the Department 5.0 PROCEDURE 5.1 Ensure that the platform is dry.

Standard Operating Procedure

2020-6-30 · Standards Laboratory SOP 005 . First edition . MONITORING AND LABORATORY DIVISION . MARCH 2014 . . • Clean up any spilled water before plugging the unit into the wall outlet. . Note: The Humilab's chamber environment sits inside a water bath. It is

Water Baths | JULABO

2 days ago · PURA water baths stand for a straightforward and safe working in the laboratory. The high-quality water baths offer a temperature stability of ± 0.15 °C 2). The working temperature range of +18 °C to 99.9 °C 1) allows a wide range of applications, such as routine laboratory work, temperature applications for samples, incubation, material .

T06-001A Care and maintenance of water baths - Techne

2013-5-17 · -40ºC to 0ºC 40% water, 40% laboratory grade ethylene glycol, 20% alcohol -20ºC to 30ºC 50% water, 50% laboratory grade ethylene glycol . If necessary, add a little tap water to the pure water in the bath. Hard tap water should also be avoided as this can cause build up of scale inside the bath and on the heating elements of the .

Standard Operating Procedure: Glassware Cleaning

2016-12-15 · careful not to spill base everywhere!!!), rinse with DI water 3 times (make sure you rinse both the inside and the outside surface). After this, transfer the glassware to the acid bath and let it soak (3 h – overnight; take care to avoid air bubbles). Once this is done, rinse with DI water 3 times, and finally leave soaking in DI water.

Cleaning Glassware | Protocol - JoVE

Care should be taken, as this bath is strongly basic and caustic, and can affect finely-calibrated glassware. To begin, add a 2 M solution of potassium hydroxide in isopropyl alcohol to a designated cleaning bucket. Next, to prolong the life time of the base bath, clean the glassware using the general "soapy water" method.

Serological Water Bath, Serological Water Baths .

2019-11-22 · Construction Details Serological Water bath: Our serological water baths are double walled convection heated units.Outer of our serological water baths is constructed out thick PCRC steel sheet duly pre-treated with primers for rust proofing and painted with air drying paint/stove enamel/powder coating.The inside chamber of the unit is made of heavy gauge stainless steel sheet of grade ss-304 .

Antibodies & Protein Biology - Fisher Scientific

The Corning LSE Digital Water Bath is a personal-sized bath with seamless chamber that can accommodate up to 6L of water or can serve as dry bath when using thermal beads. Pricing & Availability 4

Serological Water Bath, Serological Water Baths .

2019-11-22 · Construction Details Serological Water bath: Our serological water baths are double walled convection heated units.Outer of our serological water baths is constructed out thick PCRC steel sheet duly pre-treated with primers for rust proofing and painted with air drying paint/stove enamel/powder coating.The inside chamber of the unit is made of heavy gauge stainless steel sheet of grade ss-304 .

How to Develop a Laboratory Glassware Cleaning SOP | Lab .

Water Contamination – If water reacts with the final solution, you can rinse it 3 times with a reagent solution. In conclusion, the threat of contamination on your laboratory glassware significantly increases without a good SOP in place. Follow the steps above to ensure improved results.

Department Of Oncology - University of Sheffield

2015-3-31 · Standard Operating Procedure (SOP) Title: Precautions against Legionella pneumophila in water baths and incubator water pans 1. Introduction: Legionnaire's disease, caused by Legionella pneumophila, can be found in water systems held at temperatures between 25-45°C. Consequently it is important that any laboratory

Department Of Oncology - University of Sheffield

2015-3-31 · Standard Operating Procedure (SOP) Title: Precautions against Legionella pneumophila in water baths and incubator water pans 1. Introduction: Legionnaire's disease, caused by Legionella pneumophila, can be found in water systems held at temperatures between 25-45°C. Consequently it is important that any laboratory

STANDARD OPERATING PROCEDURE

2014-7-25 · 1. Ensure the sonicating waterbath contains water to at least 5 cm depth. The water level should ideally come up to the same level as your sample 2. Place your sample (e.g. a falcon tube containing a cell or soil suspension) inside a glass beaker or similar vessel, and fill the beaker with water to the same level as the waterbath. 3.

Department Of Oncology - University of Sheffield

2015-3-31 · Standard Operating Procedure (SOP) Title: Precautions against Legionella pneumophila in water baths and incubator water pans 1. Introduction: Legionnaire's disease, caused by Legionella pneumophila, can be found in water systems held at temperatures between 25-45°C. Consequently it is important that any laboratory

SOP Waterbath - Download Documents

SOP Waterbath There is document - SOP Waterbath available here for reading and downloading. Use the download button below or simple online reader. The file extension - .

What is a Water Bath? - Lab Instruments - Henan Lanphan .

A laboratory water bath is a preferred heat source for heating flammable chemicals instead of an open flame to prevent ignition. laboratory water bath. What is the function of a laboratory water bath? The application range of lab equipment water bath includes reagents warming, substrates melting or cell cultures incubation, as well as used to .